Xhhw 2 compact stranded conductors aa 8000 series.
Tc power cable xhhw.
Suitable for use in low leaking circuits requiring a dielectric constant of 3 5 or less.
Suitable for wet damp and dry locations.
Type tc power cable insulated ground xhhw 2 inners size awg size of ground wire awg outside jacket thickness pvc in allowable ampacity amps 1 outside diameter in approximate net weight lbs 1000 ft standard packaging 60 c 75 c 90 c ft.
Type tc power cable no ground xhhw 2 inners engineering specifications standards underwriters laboratories standard ul 44 ul 1277 ul 1581 ul 1685 ul 2556.
Rated for use in wet or drylocations at temperatures not to exceed 90Âșc dry or wet to meet ul 44 requirements for type xhhw 2 wire.
Icea t 29 520 210 000 btu hr.
Approved for direct burial in wet or dry locations and outdoors in cable trays where sunlight resistant rating is required.
Meets following 70 000 btu flame tests.
Suitable for installation in channels ducts wireways cable trays and conduits.
Green insulated compact stranded grounding conductor aa 8000 series as required permitted for 600 volt applications.
Approved for direct burial in wet or dry locations and outdoors in cable trays where a sunlight resistant rating is required.
Oil res i ii ensures the best protection in chemical environment.
Recognized as a general purpose building wire for use primarily in conduit or other raceways as specified in the nec it is used industrial environments where superior insulation toughness and chemical resistance are required.
Jacket is rated sunlight resistance oil resistance i and direct burial.
Type tc power cable without ground 600v xhhw 2 conductors 6 awg 4 0 awg.
Ul 1685 method 1 70 000 btu hr flame test.
Sunlight resistant in all sizes.
Astm stranding class b3 b8 and b787.
On request can have overall shield.
Suitable for installation in electrical channels ducts wireways cable trays and raceways.
Shawflex ul tray xlpe cpe power cables are suitable for use in utility and industrial applications.
Nfpa 70 nec article 336 392.
Icea t 30 520 single conductors are rated xhhw 2 for ct use 1 0 awg or larger.
Tc er cables are permitted for exposed run er use in accordance with nec reducing installation cost and time.
Xhhw 2 ct is a single copper conductor rated for ct use on 1 0 awg and larger sizes.
Nema wc 57 icea 5 73 532.
Sizes 6 awg 900 awg.
Cross linked polyethylene xlpe high heat water resistant.
Type tc er power cable 600 or 1000 volt three conductor copper cross linked polyethylene xlpe insulation xhhw 2 polyvinyl chloride pvc jacket with 1 bare cu ground.
3 c cu 600 or 1000 v xlpe xhhw 2 pvc jacket power cable with ground.